Vernier LabQuest 2 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Oprogramowanie Vernier LabQuest 2. Vernier LabQuest 2 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - USER MANUAL

2USER MANUALMEASURE. ANALYZE. LEARN.v.1.2

Strona 2 - IC Statement

LabQuest 2 Hardware 6 Audio ports are also located adjacent to the digital ports, as well as a microSD card slot for expanding disk storage.

Strona 3 - ABOUT THIS GUIDE

LabQuest 2 Hardware 7 Internal Sensors LabQuest also has several built-in sensors, including a GPS, microphone, three-axis accelerometer, tempe

Strona 4 - CONTENTS

LabQuest 2 Hardware 8 • Microphone – The internal Microphone is located on the front of LabQuest to the left of the screen, as shown below, an

Strona 5 - What’s Included

9 III. LABQUEST APP The data-collection and analysis software, LabQuest App, is the heart of LabQuest. When you turn on LabQuest, the LabQuest

Strona 6

LabQuest App 10 Table screen – See a tabular representation of your data, create calculated columns, and manually enter data. For a detailed

Strona 7 - Curve Fit

LabQuest App 11 • Open – Choose Open from the File menu to display a list of files that you have saved on LabQuest. To open a file, tap the fi

Strona 8 - Power Button

LabQuest App 12 Motion Match lab), or a smaller number for cart-based Motion Detector experiments (e.g., our Impulse and Momentum lab). • Quit

Strona 9 - Sensor Ports

LabQuest App 13 Data-Collection Controls To start data collection from any LabQuest App screen, tap Collect . During data collection, tap Stop

Strona 10

LabQuest App 14 number of samples could lead to performance issues. You can still collect data using these settings; however, you may have unde

Strona 11 - Internal Sensors

LabQuest App 15 Data Marking can be used to mark points of interest during a time-based data collection. When enabled, a Mark Data button wil

Strona 12

LabQuest 2 User Manual i SAFETY INFORMATION Federal Communication Commission Interference Statement This equipment has been tested and found to

Strona 13 - Navigating LabQuest App

LabQuest App 16 two events. Choose the proper Photogate Mode for your experiment. For more information, see www.vernier.com/til/1623/ o Mode:

Strona 14 - File Menu

LabQuest App 17 • WDSS Setup – Choose WDSS Setup from the Sensors menu to scan for, select, and configure Wireless Dynamics Sensor Systems. Tu

Strona 15

LabQuest App 18 • Graph Options – To control how the data are graphed, choose Graph Options from the Graph menu. Here you can choose the colum

Strona 16 - Data Collection

LabQuest App 19 fine adjustments to the cursor location by using the Left Examine Button and Right Examine Button located on either side of

Strona 17

LabQuest App 20 Collecting multiple runs • Store Run – You can collect several runs for comparison. Choose Store Run from the Graph menu to sa

Strona 18 - Triggering

LabQuest App 21 • Integral – The Integral tool numerically integrates graphed data. Select a region, if needed, and choose Integral from the A

Strona 19

LabQuest App 22 Interpolate from the Analyze menu, then tap on the graph. The lines associated with the Examine cursor now locate a position on

Strona 20

LabQuest App 23 o Pivot Data – This tool is only available in Data Matrix mode. It transposes the rows (usually graphed as the x-axis and repr

Strona 21

LabQuest App 24 • New Manual Column – New Manual Column creates an empty column where you can enter or generate values directly. You can add a

Strona 22 - Data Analysis

LabQuest App 25 menu to transpose the rows (usually graphed as the x-axis and representing the sampling site) with the runs (usually selected b

Strona 23

LabQuest 2 User Manual ii RF exposure warning: The equipment complies with RF exposure limits set forth for an uncontrolled environment. The an

Strona 24

LabQuest App 26 Creating Your Own Experiments If you would like to create your own content, you can do so using our online tool, LabQuest Lab C

Strona 25

LabQuest App 27 To save a LabQuest App file, 1. If saving to a microSD card or USB flash drive, make sure the drive is inserted in the approp

Strona 26

28 IV. USING LABQUEST 2 WITH A MOBILE DEVICE As part of the Connected Science System®, LabQuest 2 serves as a Data Sharing source that can wire

Strona 27

Using LabQuest 2 with a Mobile Device 29 3. Tap the Network Settings gear on the Connections App to open the Network Configuration dialog box.

Strona 28

Using LabQuest 2 with a Mobile Device 30 b. Verify LabQuest is attempting to connect to the network. The network status should say “Connecting

Strona 29

Using LabQuest 2 with a Mobile Device 31 c. Verify LabQuest is attempting to create a network. The network status should say “Connecting.”

Strona 30 - Storing LabQuest App Files

Using LabQuest 2 with a Mobile Device 32 Tap the Name field to edit the LabQuest name (e.g., LabQuest A). Tap Done to save the name. 3

Strona 31 - Exporting LabQuest App files

Using LabQuest 2 with a Mobile Device 33 2. Within the Advanced Preferences dialog box, tap the Network tab. 3. Select lockdown-mode a

Strona 32 - How Data Sharing Works

Using LabQuest 2 with a Mobile Device 34 Connect Your Mobile Device to LabQuest After setting up LabQuest as a Data Sharing source, you can the

Strona 33

35 V. USING LABQUEST WITH A COMPUTER Use LabQuest 2 with Logger Lite 1.6 (or newer) or Logger Pro 3.8.5 (or newer). Logger Lite can be downloa

Strona 34

LabQuest 2 User Manual iii CONTENTS I. GETTING STARTED WITH LABQUEST 2 ...

Strona 35

Using LabQuest with a Computer 36 Another method for manually transferring data from LabQuest to Logger Lite or Logger Pro is to choose LabQue

Strona 36

37 VI. EMAILING FROM LABQUEST If LabQuest is connected to a network with Internet access, you can email your data file, graph, text file, or sc

Strona 37

38 VII. PRINTING FROM LABQUEST You can print a graph, data table, lab instructions, your own notes, or the screen as it is currently displayed

Strona 38

Printing from LabQuest 39 3. Tap Scan for Printers. In response, LabQuest will search for available printers. Note: If LabQuest is unable t

Strona 39 - Manually Transferring Data

40 VIII. PROJECTING AND MONITORING STUDENTS’ LABQUEST DEVICES Use our LabQuest Viewer software (order code, LQ-VIEW) to view and control LabQu

Strona 40 - Deleting Data on LabQuest

Projecting and Monitoring Students’ LabQuest Devices 41 3. Tap the Viewer settings gear to open the Viewer Settings dialog box. 4. Enable

Strona 41 - VI. EMAILING FROM LABQUEST

42 IX. ADDITIONAL APPS ON LABQUEST Several accessory applications can be launched from the Home menu. It is not necessary to quit LabQuest App

Strona 42 - Printer Setup

Additional Apps on LabQuest 43 Power Amplifier From the Home screen, tap Power Amplifier to launch this app. The Power Amplifier App controls the

Strona 43 - Troubleshooting

Appendix A – 1 APPENDIX A. LABQUEST 2 TECHNICAL SPECIFICATIONS Display • 11.2 cm × 6.7 cm (13.1 cm diagonal) screen • 800 × 480 pixel color

Strona 44 - LabQuest Setup

Appendix B – 1 APPENDIX B. LABQUEST MAINTENANCE LabQuest Battery LabQuest uses a high-quality lithium-ion battery. This is the same chemis

Strona 45

1 I. GETTING STARTED WITH LABQUEST 2 What’s Included • LabQuest 2 interface • Rechargeable battery (in unit) • AC power adapter • Compute

Strona 46 - Periodic Table

Appendix B – LabQuest Maintenance Appendix B – 2 Stylus Tether LabQuest includes a stylus and a tether. If desired, you can attach the tether

Strona 47 - Stopwatch

Appendix C– 1 APPENDIX C. LABQUEST KEYBOARD LabQuest App automatically displays the keyboard when text can be entered. Standard The standar

Strona 48

Appendix D– 1 APPENDIX D. LICENSE INFORMATION This product contains certain open source software originated by third parties that is subject

Strona 49 - LabQuest Case and Screen

Appendix E– 1 APPENDIX E. WARRANTY Vernier warrants this product (with the exception of the battery) to be free from defects in materials an

Strona 50 - Getting Additional Help

Appendix F – 1 APPENDIX F. ACCESSORIES, REPLACEMENT PARTS, AND RELATED PRODUCTS LabQuest Viewer Display and contr

Strona 51 - Standard

Appendix F – Accessories, Replacement Parts, and Related Products Appendix F – 2 LabQuest 2 Stylus (Set of 5) Repla

Strona 52

Vernier Software & Technology 13979 S.W. Millikan Way • Beaverton, OR 97005-2886 Toll Free (888) 837-

Strona 53 - APPENDIX E. WARRANTY

Getting Started with LabQuest 2 2 LabQuest uses a high-quality lithium-ion battery. This is the same chemistry used in premium laptop and cell

Strona 54

Getting Started with LabQuest 2 3 4. Tap the graph to examine a point of interest. The coordinates of the point are shown in the panel to the

Strona 55

4 II. LABQUEST 2 HARDWARE Once LabQuest is connected to AC power or the battery has been charged, press the power button located on the top of

Strona 56

LabQuest 2 Hardware 5 Touch Screen LabQuest has an LED backlit resistive touch screen that quickly responds to pressure exerted on the screen.

Komentarze do niniejszej Instrukcji

Brak uwag